- Smart-UPS XL 2200/3000 VA 120/230 VAC 3U Rack Mount User Manual 5 Start Up Accessories This UPS is equipped with an accessory SmartSlot. Refer to the APC Web site, www.apc.com for available accessories. If a standard accessory, such as a SNMP card is installed on this UPS, refer to the Utility CD for user documentation.
- SUA3000XLI - APC Smart-UPS XL 3000VA 230V Tower/Rack Convertible. View the new All Products menu. Browse Products by Master Ranges. Manuals & User Guides. Software & Firmware. BIM (Building Information Modeling) Learn More. Digital Platforms. MySchneider Partner Portal. MySchneider app.
Smart-UPS 750/1000/1500/2200/3000 VA 100/120/230 Vac / 500 VA 100 Vac Tower 1 Overview Product Description The APC™ by Schneider Electric Smart-UPS ™ is a high performance uninterruptible power supply (UPS).
16
Smart-UPS XL 3U Rack Mount 2200/3000 VA 120/230 Vac; 3000 VA 100/200 Vac User Manual
Troubleshooting
Troubleshooting
Use this table to solve minor UPS installation and operation problems. Refer to www.apc.com for assistance
with complex UPS problems.
Problem and/or Possible Cause
Solution
UPS will not turn on
The battery is not connected properly.
Check that the battery connector is fully engaged.
Test
button not pushed.
Press the
Test button once to power-up the UPS and connected equipment.
The UPS is not connected to utility
power supply.
Check that the power cable from the UPS to the utility power supply is
securely connected at both ends.
Very low or no utility voltage.
Check the utility power supply to the UPS by plugging in a table lamp. If the
light is very dim, have the utility voltage checked.
UPS will not turn off
The UPS is experiencing an internal
fault.
Do not attempt to use the UPS. Unplug the UPS and have it serviced
immediately.
UPS beeps occasionally
Normal UPS operation when running
on battery.
None: The UPS is protecting the connected equipment.
Press the Test button to silence this alarm.
UPS is not providing expected backup time
The UPS battery(s) are weak due to a
Apc Smart-ups Xl 3000va User Manual Pdf
recent power outage or battery(s) are
near the end of their service life.
Charge the battery(s). Batteries require recharging after extended outages.
Batteries can wear faster when put into service often or when operated at
elevated temperatures. If the battery(s) are near the end of their service life,
consider replacing the battery(s) even if the Replace Battery LED is not yet
illuminated.
All LEDs are illuminated and the UPS emits a constant beeping
The UPS is experiencing an internal
fault.
Do not attempt to use the UPS. Unplug the UPS and have it serviced
immediately.
Front panel LEDs flash sequentially
The UPS has been shut down remotely
through software or an optional
accessory card.
None: The UPS will restart automatically when utility power returns.
A
ll LEDs are off and the UPS is plugged into a wall outlet
The UPS is shut down or the battery is
discharged from an extended outage.
None: The UPS will restart automatically when utility power is restored and
the battery has a sufficient charge.
Includes: CD with software, Installation Guide, Rack Mounting Brackets, Rack Mounting support rails, Smart UPS signalling RS-232 cable, USB cable, User Manual, Web/SNMP Management Card
List Price:
Our Price: $387.44
Over 10 million currently installed - the one you can trust
APC Smart-UPS® XL protects your data by supplying reliable, network-grade power and scalable runtime in tower or rack-mount form factors. Customers can configure up to 10 matching battery packs for runtimes exceeding 24 hours, if needed. Typical applications requiring longer runtime include critical application servers and storage, IP and PBX based voice networks, and enterprise network switches and hubs. Included PowerChute® management software provides IT administrators the comfort of safe system shutdown and advanced UPS management. Additional manageability is available through the SmartSlot, an internal accessory slot that allows installation of optional accessories to enhance performance. . Engineered with the same standards as the award-winning Smart-UPS, with over 10 million installed, the Smart-UPS XL adds the advantage of unsurpassed runtime capability for those business applications that demand continual uptime.
Features & Benefits:
Availability | |
Scalable runtime | Allows additional run time to be quickly added as needed. |
Dataline Surge Protection | Gives higher application availability by correcting low and high voltage conditions without using the |
Boost and Trim Automatic Voltage Regulation (AVR) | Provides protection of connected equipment from power surges on the data lines. |
Power conditioning | Protects connected loads from surges, spikes, lightning, and other power disturbances. |
Temperature-compensated battery charging | Prolongs battery life by regulating the charge voltage according to battery temperature. |
Intelligent battery management | Maximizes battery performance, life, and reliability through intelligent, precision charging. |
Automatic restart of loads after UPS shutdown | Automatically starts up the connected equipment upon the return of utility power. |
Automatic self-test | Periodic battery self-test ensures early detection of a battery that needs to be replaced. |
Cold-start capable | Provides temporary battery power when the utility power is out. |
Disconnected battery notification | Warns when a battery is not available to provide backup power. |
Generator compatible | Ensures clean, uninterrupted power to protected equipment when generator power is used. |
Manageability | |
Network manageable | Monitor and control the UPS remotely via included PowerChute software or APC Network Management Card (included in all models above 3kVA). |
SmartSlot | Customize UPS capabilities with management cards. |
Audible alarms | Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition. |
LED status indicators | Enables quick understanding and response to visual indicators showing UPS status. |
Disconnected battery notification | Warns when a battery is not available to provide backup power. |
Serial Connectivity | Provides management of the UPS via a serial port. |
InfraStruXure Manager compatible | Enables centralized management via the APC InfraStruXure® Manager. |
Serviceability | |
User-replaceable batteries | Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) |
Hot-swappable batteries | Ensures clean, uninterrupted power to protected equipment while batteries are being replaced |
Predictive failure notification | Provides early-warning fault analysis ensuring proactive component replacement. |
Resettable circuit breakers | Enables quick recovery from UPS overload events. |
Adaptability | |
Plug-and-Play external batteries | Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS. |
Adjustable voltage-transfer points | Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation. |
Adjustable voltage sensitivity | Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications. |
Safety | |
Safety-agency approved | Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals. |
Runtime Chart:
Click here for APC Smart-Ups XL Runtime Chart. (pop-up window)
Technical Specifications:
Output | |
Output Power Capacity | 2850 Watts / 3000 VA |
Max Configurable Power | 2850 Watts / 3000 VA |
Nominal Output Voltage | 120V |
Efficiency at Full Load | 95.00% |
Output Connections | (6) NEMA 5-15R (2) NEMA 5-20R |
Input | |
Bypass | Internal Bypass (Automatic and Manual) |
Nominal Input Voltage | 120V |
Input Frequency | 50/60 Hz +/- 3 Hz (auto sensing) |
Input Connections | NEMA L5-30P |
Cord Length | 10 feet (3.05 meters) |
Input voltage range for main operations | 82 - 147V |
Input voltage adjustable range for mains operation | 75 - 154V |
Batteries & Runtime | |
Battery Type | VRLA |
Typical recharge time | 3 hour(s) |
Replacement battery cartridge | RBC43 |
RBC™ Quantity | 1 |
Typical Backup Time at Half Load | 11.9 minutes (1425 Watts) |
Typical Backup Time at Full Load | 3.5 minutes (2850 Watts) |
Runtime Chart | Smart-UPS XL |
Extended Run Options | APC Smart-UPS XL Modular 3000VA 120V Rackmount/Tower |
Communications & Management | |
Interface Port(s) | DB-9 RS-232,RJ-45 10/100 Base-T,USB |
Pre-Installed SmartSlot™ Cards | AP9619 |
Control panel | LED status display with load and battery bar-graphs and On Line : On Battery : Replace Battery : Overload and Bypass Indicators |
Audible Alarm | Alarm when on battery : distinctive low battery alarm : configurable delays |
Emergency Power Off (EPO) | Optional |
Surge Protection and Filtering | |
Surge Energy Rating | 540 Joules |
Filtering | Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449 |
Physical | |
Maximum Height | 3.40 inches (86 mm) |
Maximum Width | 17.00 inches (432 mm) |
Maximum Depth | 26.70 inches (678 mm) |
Net Weight | 103.00 lbs. (46.82 kg) |
Shipping Weight | 125.00 lbs. (56.82 kg) |
Shipping Height | 9.84 inches (250 mm) |
Shipping Width | 23.46 inches (596 mm) |
Shipping Depth | 38.58 inches (980 mm) |
Color | Black |
Units per Pallet | 8.00 |
Rack Height | 2U |
Environmental | |
Operating Environment | 32 - 104°F (0 - 40°C) |
Operating Relative Humidity | 0 - 95% |
Operating Elevation | 0-10000 feet (0-3000 meters) |
Storage Temperature | 23 - 131°F (-5 - 55°C) |
Storage Relative Humidity | 0 - 95% |
Storage Elevation | 0-30000 feet (0-9000 meters) |
Audible noise at 1 meter from surface of unit | 55.00 dBA |
Online Thermal Dissipation | 300.00 BTU/hr |
Conformance | |
Regulatory Approvals | BSMI,CSA,FCC Part 15 Class A,NOM,UL 1778,VCCI |
Standard Warranty | 2 years repair or replace |
Equipment protection policy | Lifetime: $150,000 |
Documentation:
Download the APC Smart-UPS XL SUM3000RMXL2U Data Sheet (PDF).
Pricing Notes:
- Pricing and product availability subject to change without notice.
- Note: Shipping charges may vary depending on the selected unit's weight or the quantity of units selected. As a result, the shipping charges may change from the value you receive at checkout. A customer representative will confirm these changes with you if they occur before processing your order.
Apc Smart Ups 2200va Manual
List Price:
Our Price: $387.44
Apc Smart Ups 3000va Manual
Our Price: $34.00
Apc Smart-ups Xl 3000va User Manual 2016
Apc Smart Ups User Manual
Our Price: $959.00